Different kinds of fasteners are used in ITER for the fixation of functional and structural in-vessel diagnostic components. The fasteners should retain initial tightening preload in vacuum under neutronic irradiation, thermal cycling and vibrations. These conditions can lead to incidental unscrewing of some bolts and nuts if they are not locked properly. They shall be equipped with some locking features which in most cases shall be remote handling compatible. One of the candidates on a role of a locking mechanism is Spiralock type thread. Custom designed so called First Wall Samples (CuCrZr) with M16 fine thread and standard M8 bolts (316L) were the subject of our studies. ITER-like thermal cycling alternating with vibration tests were applied to the components. Fasteners' loosening was monitored via periodic torque audits. For comparison with the Spiralock thread, tests with normal metric threads were also performed under the same experimental conditions.




Latest news

Project completed!
24 August 2018
The jigs were shipped to the ITER Organization to Cadarache, France in mid-January 2022 and they will be used for mounting of the sensors from April onwards.